DaqPRO 
The Professional's Choice  

An eight-channel portable data acquisition and logging
system with graphic displays and built-in analysis functions

Online Connectivity Enables Virtual Data Logging

DaqPRO is battery operated and is capable of sampling, processing and displaying measurements without connecting to a computer. Designed to serve the needs of professional data loggers, DaqPRO is a professional, cost-effective, compact and stand-alone data logging system that can be used with a wide variety of applications. This 16-bit, high-resolution, eight-channel data logger offers the pros graphic displays and analysis functions for measuring voltage, current and temperature in real-time.
 

 

Fast, High Resolution Data Logging

With its high resolution and fast Analog to Digital converter (ADC), DaqPRO meets the majority of data logging requirements in most industrial applications. Its unique ability to display measured values and analyze them in real-time on a graphical interface minimized the need to download collected data to a computer for further analysis.

Applications

  • Quality assurance
  • Plant and machine condition monitoring
  • Field monitoring stations
  • Automotive testing
  • HVAC
  • Plant trouble shooting
  • Electricity transients failure detection
  • Monitoring environmental conditions
  • Food, drug and electronic equipment storage
  • Water quality testing
  • Research
     

Accessories

  • Carrying case
  • NTC temperature probe
  • Solar cell and battery for field data logging
  • Weather box complies with the IP-67 standard for protecting DaqPRO while working in field applications
     

Product Features

  • Stand-alone operation - samples and displays measurements without being connected to a PC
  • Operates on a 7.2V rechargeable battery with over 500 charging cycles
  • High sampling of up to 4,000 samples per second in channel No. 1
  • Large data storage of 512KB RAM
  • Large graphic display showing collected data as measured values, graphs or tables
  • Setup via the DaqPRO keypad
  • Fast communication channels: USB
  • Multiple logging storage of up to 100 sampling sessions
  • Ability to scale readings into meaningful engineering units e.g. bar, ppm
  • Built-in clock and calendar keeps track of time and date for each data recording
  • On screen text editing for adding more information to the collected data
  • Powerful analysis software for Windows 98, 2000, XP and Vista
  • Most economical eight channel data logger on the market
     

Specifications

Click here to view DaqPRO Specifications (PDF Format)
 

DaqPRO 5300 8-Input Channels Measure

0 – 24.000 mA

  • Range 0 to 20mA
  • Resolution 0.47µA
  • Accuracy ±0.5% of reading Loop impedance - 21Ω

0 – 50.000 mV

  • Range 0 to 50mV
  • Resolution 3µV
  • Accuracy ±0.5% of reading
  • Loop impedance - 50Ω

0 – 10.000 V

  • Range 0 to 10V
  • Resolution 200µV
  • Accuracy ±0.5% of reading
  • Loop impedance – 125KΩ 

Temperature NTC-1

  • NTC – 10KΩ resistor
  • Range -25 to 150ºC
  • Resolution 0.05ºC
  • Accuracy 0.5% of reading

Temperature NTC-2

  • NTC – 100KΩ resistor
  • Range -25 to 150ºC
  • Resolution 0.05ºC
  • Accuracy 0.5% of reading 

Temperature PT100 2 wires

  • Range -200ºC to 400ºC
  • Resolution 0.1ºC (7mΩ)
  • Accuracy ±0.5% of reading 

Temperature PT100 3 wires

  • Range -200ºC to 400ºC
  • Resolution 0.1ºC (7mΩ)
  • Accuracy ±0.5% of reading

Temperature thermocouple J

  • Range -200ºC to 1,200ºC
  • Resolution 0.1ºC (1µV)
  • Accuracy ±0.5% of reading
  • Cold junction compensation ±0.3ºC

Temperature thermocouple K

  • Range -250 to 1200ºC
  • Resolution 0.1ºC (1µV)
  • Accuracy ±0.5% of reading
  • Cold junction compensation ±0.3ºC

Temperature thermocouple T

  • Range -200 to 400ºC
  • Resolution 0.1ºC (1µV)
  • Accuracy ±0.5% of reading
  • Cold junction compensation ±0.3ºC

Frequency input (input 8 only)

  • Zero crossing detector
  • Sensitivity 20mV
  • Range 0.3Hz to 1000Hz
  • Resolution 50µs

Internal Temperature

  • NTC – 10KΩ resistor
  • Range -30 to 70ºC
  • Resolution 0.05ºC
  • Accuracy 0.5% of reading